Welcome to the American HVAC Parts Blog page! This blog is to help with many of those questions regarding problems with your heating or air conditioning equipment. Here you will find many answers as well as helpful tips to keep you going through the changing seasons. Once you have found the answer you are looking for, you can then take the next step in searching for your needed parts by visiting us at www.americanhvacparts.com or you can reach us toll free at (866) 432-8551.



Monday, June 27, 2011

Determining the size of your outdoor heat pump condenser unit: Is it properly sized for the home?

In most all cases, the equipment model number has the size of the unit included in the model number. This is referred to as the horsepower (H.P.) or as tons, but ultimately it is referring to the BTU’s (British Thermal Units). It is very important to have the proper sized system for your home to prevent excessive use and high energy costs, as well as adequate efficiency. For example, say your model number looks something like 58MAV036000AAAA… this is a typical sequence for a Carrier unit. The 036 indicates the BTU’s, so that translates into 36,000 BTU’s.
This information as stated before will also be referred to as H.P. or tons. One ton is 12,000 BTU’s, or one H.P.. So with a 036 or a 36,000 BTU unit, this would be known as a 3 ton unit, or a 3 H.P.. Pretty simple right? Next I’ll address how to make sure the unit is the proper size for your house.
Easiest rule of thumb is just to remember 500 square feet is equivalent to one ton. So if your house has 1500 square feet, that would be how many tons? If you said 3 you’re correct. Not really rocket surgery is it? Now we can review by taking a look at the chart I have provided below.
500 square feet = 12,000 BTU’s = 1 Ton = 1 H.P.
1000 square feet = 24,000 BTU’s = 2 Tons = 2 H.P.
1500 square feet = 36,000 BTU’s = 3 Tons = 3 H.P.
2000 square feet = 48,000 BTU’s = 4 Tons = 4 H.P.
2500 square feet = 60,000 BTU’s = 5 Tons = 5 H.P. and so on…
So there you have it. Sizing and verifying the condenser or heat pump size broken down for the easiest calculation. If you have any questions, please feel free to contact us toll free at (866) 432-8551 or visit us at http://www.americanhvacparts.com/

Thursday, June 23, 2011

Heat Pump, Condenser or Furnace, OH MY! Choosing the proper replacement thermostat

In this week’s episode, we are going to explore the process of choosing the proper thermostat for your system. There are quite a few different choices, so it is important to know the type of system you have. With all the different systems, this can be a bit confusing, but don’t fret… we are here to help. Alright then, let’s start by listing the various types of thermostats and what they are used with.
There are:
•1 Heat/1 Cool – Used with standard gas or electric heat and electric a/c units & are typically 24 volt
• 2 Heat/1 Cool – Used with heat pump, gas or electric heat units and electrical a/c units & are typically 24 volt
• 2 Heat/2 Cool - Used with heat pump, gas or electric heat units and electrical a/c units & are typically 24 volt
• 3 Heat/2 Cool – Used with Multi Zone, heat pump, gas or electric heat units and electrical a/c units & are typically 24 volt
• Millivolt – Used with millivolt (Usually wall heating units or cooling units)
• Line Voltage – Used with 120/240 volt systems (Usually like an attic fan application)
• Evaporator Cooler – Used with evaporator coolers

These can also have variances of but not limited to…
• Programmable
• Non-Programmable
• Commercial
• Residential
• Wireless
• Heating only
• Cooling Only
• Phone controlled
• Internet controlled
• Remote Controlled etc…
Then there are the different manufacturers. Here are some of the most common types:
•Honeywell
• Robertshaw
• Johnson Controls
• Totaline
• White-Rodgers
• Lux

The best advice that can be given to replace a thermostat is to compare to what you already have. This gives you a good place to start in terms of what you will need. You can also take a part number from your existing thermostat and use that to either locate the direct replacement or a functional equivalent. If you are just not sure, you can always visit www.americanhvacparts.com or call toll free to (866) 432-8551 for assistance in finding the perfect fit replacement for you and your system’s needs. It is NOT recommended that you just pick one because you like how it looks, or the back light is a pretty blue or any other non-educated reason because it probably won’t work once you get it. And most places will not take back electrical parts, so if you just aren’t sure get the help you need. That is what we are here for, you the homeowner and helping you make the right choice the first time.

Monday, June 13, 2011

Your compressor failed… Now what?

Well this is a kind of bittersweet situation. A compressor is the most expensive part that can go out in your air conditioner or heat pump, so replacing it can become fairly pricey. This is also an item that cannot be replaced without the assistance of a professional, so there will be some technician costs that will be incurred as well. Already sounds pretty depressing right? Well, the plus side of this is that you don’t have to replace the whole system as some technicians may try to tell you. This is false. A compressor can be replaced fairly easy. It just takes the right information.
First, you will need to locate the model number from the condenser or heat pump. If this information is not available, the next step is to get the model number from off of the compressor itself. Once you are armed with the right information, you can contact a company such as www.americanhvacparts.com and provide what you have. Locating the correct replacement is going to be simple for them at that point.
The key here if you are wanting to purchase the replacement on your own instead of from the technician, is that you will want to make sure to arrange installation for when you get the compressor. Many technicians will not want to come out and install a part that you have obtained, because they want to sell you the item as well as do the work. So that’s why it is important to have a pre arranged agreement with your tech so that there are no surprises for him or you.
Now that the compressor has arrived and the technician is on his way, here is a rundown of what to expect. The tech will come out and begin to open the unit. Once the old failed compressor is exposed, your tech will take what is called a vacuum pump and evacuate the refrigerant from the system. Condensers and heat pumps are highly pressurized with the refrigerant gas, so that is why it is necessary to have this done first. After the refrigerant has been recovered and the system completely pumped down, the tech will next cut out the old compressor. After it has been removed, the new compressor can be seated in the unit and the lines brazed or welded in. The next step in the process is to pump the system back up with the refrigerant. The tech should now run a pressure test to make certain that there are no leaks. Assuming the job was done properly, that’s pretty much that. The time you may pay out to the technician will usually average around $300-$500, as this will also include the charges for the new refrigerant.
Now turn your system on and enjoy the cool air and the savings you made by replacing the compressor and not the whole system.

Monday, June 6, 2011

How to install an aftermarket condenser fan motor

AmericanHVACParts.com does not encourage or recommend that any uncertified or unqualified persons attempt these repairs. This information is for informational purposes only and AmericanHVACParts.com will not be held liable for any damages or injuries by attempting to make these repairs. 

The first thing to do to get this process going is to identify which motor you need. To do this, the best way to start is by going to the condensing unit or heat pump that the motor is coming out of and getting the model and serial numbers. There should be a label affixed to the outside of the unit, usually towards the back of the unit which will most likely be the side closest to the house or building. Sometimes, the unit has been installed so close, you will have to use a mirror and try to decipher the model number backwards in the reflection, but nonetheless, it can be done. In the event that the label is illegible or has been bleached away from years of sun exposure or other elements, there is still a way to make the identification on what you will need.
Ok, so the model number just isn’t there. What’s next? Now the unit will have to be opened up to get the information from the motor itself. If you are not familiar with what you are doing, we highly recommend that you retain the services of a professional to assist you. Now that the unit is opened up, your attention should be directed to the condenser motor. There will be a label on the side of the motor that will have lots of information on it. The first thing you will want to look for is any part or model numbers. Typically if the motor has never been replaced, there will be 2 identification numbers there. The important thing is to get as much information as possible. Get all part numbers, model numbers, just any numbers at all. Because if for any reason the numbers are not able to be located, we can assist you in finding it by the specifications. The key information besides part numbers in locating a motor are as follows:
-RPM’s
-Horsepower
-Voltage
-Phase
-Frame or Diameter size
-Shaft size
-Rotation (Not so important as most aftermarket motors are reversible)
With this information, a replacement can be matched up fairly easy. Now that a replacement has been found, it’s time to get that beauty purchased and on its way to you and don’t forget the capacitor. You’re more than half way there. Now that you have the motor, again we recommend retaining the services of a professional, but even they might have some confusion as to how to install it, so these are instructions for their convenience as well as for your knowledge. AND ALWAYS DISCONNECT POWER TO THE UNIT BEFORE ATTEMPTING ANY KIND OF REPAIRS.
Most OEM condenser motors have only 3 wires… a power wire, a common wire and a capacitor wire. The old motor would be connected to a dual capacitor (described in earlier posts) which the new motor will NOT be using. So the old motor will be disconnected from the dual capacitor and removed, leaving the dual capacitor in the unit as it will continue to run your compressor. The new motor will come with 5 wires in almost all cases when replacing an OEM motor with an aftermarket motor. The wires will be black, purple, green, brown and brown with a white stripe. There will also be 2 wires that come out from the back of the motor and go back into the motor. These are connected in the middle with a white plastic plug, but we’ll come back to that later. The black and purple wires will connect to the contactor on the opposite side of the contactor from where the live power wires that come from the house are connected. The brown and brown with white will go to the new capacitor, one wire to each of the 2 terminals. It doesn’t matter which each brown wire goes to as you cannot reverse the polarity of a single run capacitor. Next affix the green wire to the actual unit casing to establish a ground. After everything is wired in and the unit put back together, everything should fire up fine. In the event that the blade is spinning in the wrong direction, disconnect power once again, gain access to the motor and locate the 2 wires on the back of the motor that connect with the plastic white plug. To reverse the rotation, just pull that plug apart, flip one side over and plug it back together. And there you have it.
AmericanHVACParts.com does not encourage or recommend that any uncertified or unqualified persons attempt these repairs. This information is for informational purposes only and AmericanHVACParts.com will not be held liable for any damages or injuries by attempting to make these repairs.  

Wednesday, June 1, 2011

How to find the proper size supply or return grille for your home or office

The first thing to do when you have grilles to replace is identify the type and style. Is it a supply where the air blows out of the register? Or is it a return that the air gets sucked back into the system? Next is to identify the style. There are 3 basic styles to choose from. There is stamp faced, where the louvers have been stamped into and raised up out of the metal. Bar style is where the grille has a frame and individual bars making up the louvers. Then there is curve blade, where the blades actually extend out from the face of the register and curve, creating a more direct and intentional air flow.

When it's time to replace your grilles, which are often also called vents or registers, the information needed is pretty basic and easy to get. Many people will measure the overall size of the grille, but this is the incorrect way to go about it and will land you with a grille that is just too big to fit. The proper way to size up your register is to actually remove the register from the wall, floor or ceiling and set it aside for now.

Next, you will actually be measuring the cut out, or hole size. You will need to get the width as well as the height, and then present the measurements in this order when obtaining your replacement. For example, let's say you measured a width of 16" and a height of 10". If you ask for a 16"x10", you will get the proper size. But, if you ask for a 10"x16", you will wind up with a register that is 10" wide and 16" tall, so the orientation will be backwards. It will still fit, but the air flow will not be proper for your application. And it will look kind of funny and out of place.

The overall dimension of the new grille will be larger than your measurements, and this is fine. That is why we measure the hole and not the overall dimension. There will be a 1 7/8" lip going around the whole grille, and this is to cover paint marks, holes etc.

And that's really all there is to finding a replacement register. You can take a look at all the various types and styles by clicking on the link for supply grilles, and for returns. And if you are interested in some specialty wood or decorative grilles, you can click here.

Wednesday, May 25, 2011

5 myths revealed: What your technician may or may not tell you…

Parts are obsolete:
This is more often than not a false claim. Repair parts are made by a variety of different manufacturers, so just because the original part you had may no longer be available, there is usually a functional if not exact direct replacement out there. It just takes a little digging, and sometimes you might have to be the one to pick up the shovel. You have to keep in mind, it is more time efficient and profitable for the technician to just replace a unit versus having to try and source your part and then come back and install it. And some companies just don’t have enough cross reference information or tools available to be able to find that other replacement. The internet is a very powerful tool. Before succumbing to the technician’s claims, you may just want to take a trip on the information super highway.
The manufacturer is out of business:
Again, this is usually false. There are a few companies that have fizzled out over the years, but that is literally only a few. And just because they might have gone out of business, it still does not mean that you can’t find a replacement part. Think of your unit like a car. Sure, the body style and emblem tells you what brand it is such as a Chevy, but not all of the components inside and under the hood are made by Chevy. They source out different companies to make certain parts for them and then they install them into the vehicle. This is the same with heating and air conditioning units. You may have a Lennox unit, but the contactor could be made by White-Rodgers, the motor by GE, the circuit board by Robertshaw and a compressor by Copeland. If your repair part can’t be found by the Lennox unit model number, it usually can be found by a part number from the part itself.
R-22 compressors are no longer available:
We hear this one a lot. While it is true that R-22 refrigerant is being phased out, this is not going to be til around 2018. In the meantime, Copeland, Bristol and Tecumseh among other manufacturers will continue to produce the R-22 units. They are not defunct, they are not illegal.
The repair part you picked up is incorrect for your unit:
While this is quite a possibility depending where you go for your part and what information you used to find it, I can speak for our company in saying that this is an absolute rarity. As long as you provide the correct information from your unit or part, and not from a manual that came with the unit then you should be in good shape. The manuals that come with the units are sometimes a reference guide for a gambit of units in the same series, so it won’t provide the correct or complete model number information. And sometimes the manual that you get isn’t for the unit you actually have at all, so always reference the equipment or part for the part or model number information. That being said, with the correct information, sometimes the repair part has been upgraded or switched to a different manufacturer, which will usually result in a part that looks a lot different. So what. Like the old saying goes, looks can be deceiving. And there are some technicians that will tell you that you have the wrong part. Some because they are unaware of the upgrade or change in manufacturer, and some because they would rather you buy the part from them. If they tell you the part you got is incorrect, before you take their word for it, contact the company you placed the order with and go over everything once again. What can usually be done here is the company will double check all cross references that were made against the part that you were shipped, and assuming the information all points back to the same part, documentation and proof along with replacement wiring instructions can be provided. Now, I cannot speak for all other companies, but I can say that for certain with parts purchased from AmericanHVACParts.com.
And the 5th and BIGGEST myth of all…
Your unit or entire system needs to be replaced:
This is the most common and most outrageous claim we tend to hear from our customers. For even the smallest and most common parts, customers will call us and explain how they were told that because their contactor or capacitor or motor is bad that the entire unit or even worse, the entire system is in need of replacing. This can sometimes, on a very rare occasion be true. VERY RARE. We would highly advise that you either get a 2nd or 3rd opinion, or simply call us and describe the situation. Most often it is a quick simple fix that can be done by yourself without having to call out a technician again, and for a fraction of the cost of what the whole new replacement system would cost. I can’t say it enough, use the internet. That’s what it is there for is information, and there is a wealth of it out there to be found. You just might surprise yourself with how much time, money and headache can be saved just by crawling along the world wide web or simply call us at (866) 432-8551.

Monday, May 16, 2011

Split System Air Conditioner Not Working: Diagnosing the problem

It’s the peak of summer, and the heat couldn’t be any worse. You go to your thermostat and turn on the air conditioning expecting an icy summer treat to bring the temperature in your house down to a comfortable temperature. The blower kicks on, but there is no cool air coming out of the vents. Your mind goes into a panic with thoughts racing through your head… What should I do? Do I call a technician? How much is this going to cost me? Do I have to replace the whole outdoor unit? Don’t fret just yet. There are ways of diagnosing the system fairly easy without having to be a technician or calling one out, and odds are it probably is an easy and affordable fix.
Ok, so where do you start? That is a good question. First off we need to identify what’s happening at the unit. So with the thermostat set for cool and the fan inside running, you will need to go to the outdoor unit and make a visual and audible observation. These split condenser units are fairly simple with only a few parts in them. There would be a compressor, a contactor, a fan motor, a fan blade, and a capacitor.




Now let’s run down the items and determine what’s happening here.
Is the fan motor running and the blade spinning?
Is the compressor running?
Are both the compressor and fan motor not running at all?
If either of the motor or the compressor are working but the other item is not, then this is a pretty simple diagnosis. If the compressor is running but the fan motor is not, or vice versa, chances are it is just a capacitor issue. This is definitely the least expensive part to purchase if you are uncertain. To tell, simply take a stick and fish it down through the fan guard and try to spin the blade. If it kicks on, it is a bad capacitor for sure. If not, then your motor is bad and you would want to replace both the motor and the capacitor. If the motor is running and the compressor is not, then by changing the capacitor you will know if the compressor is bad by whether or not it fires up at that point. If after changing the capacitor the compressor does not kick on, then your compressor is bad. If neither of the compressor or motor is running, you can easily find the culprit to this problem. You will need to locate the access panel and remove it. If you follow the power lines coming from the house to the unit, the part that they are going to connect to is the contactor. On the top of the contactor there is a plunger style button, which when electricity is applied to the contactor coil, it becomes a magnet and pulls in that button bridging the live power across the contactor thereby giving power to the compressor and fan motor. If you turn the unit on and the button is not pulling in, this will tell you that either the contactor is bad, or the thermostat is not providing power to the contactor. To know for sure, take something non-conductive, like a stick, and push in the button. If you do this and the power to the compressor and fan kicks on, then we have identified the location of the problem. All there is left to do is verify that there is power coming to the contactor from the thermostat by using a volt meter on the thermostat wire. If there is power, the contactor is bad. If there is none, then there is a break somewhere between the thermostat and the wire. Tracing the wire to the break will tell you that the thermostat is either not sending a signal, or if the wire has a dead spot.
And that’s pretty much the jist of diagnosing your condenser problems. If you have determined what part you need, you can visit our website or call us and we would be happy to assist you in locating the part you need. Have a cool summer.